The space between the inside of the handrail and the wall or any other obstruction must be at least 1 1 2.
Wall mounted handrail bracket spacing code.
Ibc 1014 4 key exception.
F the mounting of handrails shall be such that the completed structure is capable of withstanding a load of at least 200 pounds applied in any direction at any point on the rail.
Yet if the railing is pushed out too far there is the risk of violating another section of code that provides for 27 inches of walking width between the two railings of a double railing staircase.
Handrail must be continuous.
The handrail shall be designed to provide a grasping surface to avoid the person using it from falling.
The spacing of brackets shall not exceed 8 feet.
The spacing of brackets shall not exceed 8 feet.
In other words it can t be wobbly and unstable.
Ibc 2000 1 1 2 inch minimum.
Ansi a117 1 1 1 2 inch minimum.
For the typical guard rail you want unsupported spans no greater than 8 in most cases.
Typical code requirements state that the top rail must be able to withstand a 200lb outward force.
For example the minimum hand clearance between the railing and the wall that it is mounted on is 1 1 2 inches.
Handrail brackets or pickets attached to the bottom of the handrail that do not project horizontally beyond the sides of the handrail within 1 5 of the bottom of the handrail shall not be considered obstructions 9.
E handrails projecting from a wall shall have a space of not less than 1 1 2 inches between the wall and the handrail.
Irc 2003 1 1 2 inch 38mm minimum between wall and the handrail.
A handrail or grab bar and any wall or other surface adjacent to it needs to be free of anything sharp or abrasive.
In hollow wall applications handrail brackets must be fastened to wood studs or appropriate blocking must be provided to meet structural requirements.
Mount the wooden handrail with screws from the bracket s assembly kit.
E handrails projecting from a wall shall have a space of not less than 1 1 2 inches between the wall and the handrail.
Codes also generally require that there be a 1 1 2 clearance between the underside of the handrail and any obstruction including the horizontal bracket arm.
Clear space between a handrail and a wall or other surface shall be not less than 1 5.
There is an allowance however for variations in the handrail size for every 1 2 of additional perimeter dimension over 4 you may subtract 1 8 from the clearance.
Cast handrail bracket with tapped hole mounted with hanger bolt and lag screw expansion shield.
A handrail and a wall or other surface adjacent to the handrail shall be free of any sharp or abrasive elements.