Heat pump systems water to air geothermal heat pump systems water to water geothermal heat pump systems air to air heat pump systems controls wi fi thermostats accessories radiators air handling units and cased coils geothermal accessories boiler controls indirect hot water tanks.
Water to air heat pump schematic.
Figure 1 shows a piping schematic for an air to water heat pump system that provides zoned heating using radiant panels and zoned cooling dehumidification using small air handlers.
Water to water heat pumps require constant water flow through both the evaporator and condenser while operating.
Air to air heat pump systems.
Air to water heat pumps air to water heat pump.
Flow starvation can occur when the heat pump serves a zoned hydronic distribution system.
The arrangement in figure 13 is a series configuration and the heat pump evaporator is supplied with energy from the solar system.
Types of heat pumps air source heat pump systems.
Domestic heaters that are powered by oil gas and electricity heat water up to around 70 80 c whereas ground or air source heat pumps used for hot water may only be efficient up to 55 c.
Schematic diagram of a domestic water to air heat pump system series arrangement.
By moving heat indoors the heat pump system causes your interior areas to feel warmer.
Both zones must operate in the same mode e g heating or cooling at the same time.
Colmac heat pump water heaters offer commercial and industrial users of sanitary hot water an energy efficient means of heating water to temperatures as high as 185 f 85 c in a single pass.
These units work in a similar manor but without the reversing valve.
On the other side of the plate heat exchanger water is being cycled through a hot water storage tank.
Our water heating system units can provide superior energy storage through a buffer tank.
If either flow stream is restricted the heat pump quickly shuts itself off due to refrigerant pressure limits.
A hydronic heat pump has many advantages over conventional air to air heat pumps.
These heat pump water heaters use the same operating principle as an air conditioner or domestic refrigerator.
Even if it s cold outside abundant warmth still exists in outdoor air.
The high pressure high temperature vapour refrigerant leaves the compressor but this time heads into a plate heat exchanger.
By storing the heat energy we can distribute it to any source we want such as a domestic hot water heating and cooling fans finned radiators hydronic in floor heating.
The industry s only water source heat pump with automatic 3 speed fan control provides greater and more versatile comfort control than its 2 speed counterparts an economical approach for comfort conditioning requirements in both traditional and geothermal replacement renovation and new construction applications.
Colmac heat pump water heaters.
Flow to all heating and cooling zones is provided by a single variable speed.